Pressure - Temperature Service Ratings for F9 Forged Steel Socket Welding and Threaded Fittings
Service Temperature (°F) | Nominal Pressure Rating | ||
---|---|---|---|
2000 LB. | 3000 LB. | 6000 LB. | |
100° | 2000 | 3000 | 6000 |
150° | 1970 | 2950 | 5915 |
200° | 1940 | 2915 | 5830 |
250° | 1915 | 2875 | 5750 |
300° | 1895 | 2845 | 5690 |
350° | 1875 | 2810 | 5625 |
400° | 1850 | 2775 | 5550 |
450° | 1810 | 2715 | 5430 |
500° | 1735 | 2605 | 5210 |
550° | 1640 | 2460 | 4925 |
600° | 1540 | 2310 | 4620 |
650° | 1430 | 2150 | 4300 |
700° | 1340 | 2010 | 4025 |
750° | 1245 | 1870 | 3745 |
800° | 1155 | 1735 | 3470 |
850° | 1060* | 1595* | 3190* |
875° | 1015* | 1525* | 3055* |
900° | 970* | 1455* | 2915** |
925° | 925* | 1375* | 2775** |
950° | 880** | 1320** | 2640** |
975° | 830* | 1250** | 2500** |
1000° | 810** | 1215** | 2430** |
1025° | 665** | 1000** | 2000** |
1050° | 520** | 785** | 1570** |
1075° | 420** | 625** | 1255** |
1100° | 315** | 470** | 945** |
1125° | 260** | 390** | 785** |
1150° | 210** | 315** | 630** |
1175° | 175** | 265** | 530** |
1200° | 145** | 215** | 430** |
* Product used within the jurisdiction of Section 1, Power Boilers of the ASME Boiler and Pressure Vessel Code is subject to the same maximum temperature limitations placed upon the material in Table P7, 1952 edition thereof.